Rosemount 2130 Enhanced Vibrating Fork Liquid Level Switch

Based on the same vibrating short fork technology as the Emerson Rosemount 2120, the Emerson Rosemount 2130 delivers increased safety with certification to the IEC 61508 safety standard for SIL 2 safety instrumented systems with an SFF greater than 90% (subject to selected output type), and extends our coverage to include the more challenging applications in many industries.

Features include a complete range of process connections, wide choice of housing and wetted parts materials, different switching functions, extended fork lengths and hazardous area approvals, making the Emerson Rosemount 2130 suitable for virtually all liquids.

The Emerson Rosemount 2130 continuously performs advanced instrument health self-checking of the fork and sensor. These diagnostics can detect external damage to the forks, internal damage to the sensor, excessive corrosion and over-temperature.

The Emerson Rosemount 2130 can withstand liquid temperatures from -94 to 500 F (-70 to 260 C) and process pressures to 1450 psig (100 barg).

The Emerson Rosemount 2130 has been TUV tested and approved for overfill protection according to the German DiBt/ WHG regulations. It is certified under safety devices for tanks and piping related to water pollution control.

  • Function is virtually unaffected by flow, bubbles, turbulence, foam, vibration, solids content, coating products, liquid properties, and product variations
  • No need for calibration and requires only a minimum amount of installation
  • Easy terminal access, and safe and easy hook-up with electrical protection features
  • No moving parts or crevices means virtually no maintenance
  • Advanced electronic instrument health and self-checking of the fork and sensor
  • Visible Heartbeat LED shows device status and health
  • Adjustable Switching Delay for turbulent or splashing applications
  •  Local Magnetic Test Point makes functional test easy
  • Short fork for minimized protrusion into pipework
  • Extended lengths up to 157.5-in. (4 m)
  • Fast Drip Fork Design gives quicker response time
  • General area, Explosion-proof/Flameproof and Intrinsically Safe options
  • Increased safety with certification to the IEC 61508 safety standard for SIL 2 safety instrumented systems.
>Previous  >Next  
Specifiction Packing
  • Features

    • Stainless steel or aluminium housings
    • 316 SST, Alloy C, or ECTFE/PFA co-polymer coated 316 SST wetted parts
    • Extreme process temperatures from C94 to 500 F (C70 to 260 C)
    • Stainless steel thermal tube moves the electronics away from the process
    • Process pressures to 100 bar g/1450 PSI
    • Enhanced instrument health ⁄ self-checking diagnostics of the fork and senor
    • Visible Heartbeat LED shows device status and health (while cover is removed)
    • Threaded, hygienic, or flanged process connections
    • Magnetic test point on side of housing
    • Easy terminal access
    • Electrical hook-up is safe and easy with electrical protections
    • Adjustable switching delay
    • Fast Drip fork design for responsive switching

    Benefits

    • Increased safety with certification to the IEC 61508 safety standard for SIL 2 safety
    • instrumented systems
    • Minimal amount of installation time
    • No mechanical moving parts or crevices
    • Maintenance free
    • Resistant to plant vibration
    • Short fork technology for minimized protrusion
    • Replaceable electronics cassettes with versatile switch outputs
    • Intrinsically safe
    • Explosion-proof
     
    Specifications
     
     
    Key Specification
    Approvals
    Certification Explosion-proof, Intrinsically Safe and Ordinary Location
    Approved for overfill protection according to DiBt/ WHG regulations.
    Certificate number: Z-65.11-519
    Construction
    Housing Stainless steel or Aluminum
    Wetted Material 316L stainless steel (1.4404), or Corrosion resistant nickel alloy C
    IP Rating IP66 ⁄ 67
    Connections
    Process Connection Threaded, flanged, or hygienic
    Electrical
    Electrical Connection Terminal block
    Output Direct load switching (ac or dc),
    DPCO Dual Relay,
    Fault and Alarm (2 x SPCO) Relays,
    PNP for Programmable Logic Controllers
    NAMUR, or
    8/16 mA
    Self-check, condition monitoring Yes
    Operating Conditions
    Process Temperature -94 to 500 F (-70 to 260 C)
    Process Pressure 1450 psi at 122 F (100 barg at 50 C)
    Note:
    1. Extended lengths are available. 
    2. Suitable for use with Rosemount 702 for Wireless applications
1pcs per carton