Location : Home > Products
Products
Rosemount 3144p temperature transmitter
Performance of PT100 Temperature Transmitter 4-20mA 3144P : *Universally progammable with HART-protocol for various input signals *Two-wire technology, analogue output 4 to 20mA *Highly accurate in entire operating temperature range *Wide voltage supply range *Customer specific measurement range settings *Simple and user friendly software *Multiparametric backlight rotatable LCD display Application of PT100 Temperature Transmitter 4-20mA 3144P : * Temperature Field Transmitter with HART-protocol convert various input signals into a scalable 4 to 20mA analogue output signal *Input Resistance thermometers(RTD) Thermocouples(TC) Resistance transmitters(ohm) Voltage transmitters(mV) Parameters of PT100 Temperature Transmitter 4-20mA 3144P : Digital Accuracy 0.10 C (0.18 F) for Pt100 RTD D/A Accuracy 0.02% of span (Applies to HART/4-20 mA devices) Ambient Temperature Effects 0.0015 C (+0.001% of span for HART/4-20 mA devices) per 1.0 C (1.8 F) change in ambient for a Pt100 RTD Stability (RTDs) 0.1% of reading or 0.1 C, whichever is greater, for two years 0.25% of reading or 0.25 C, whichever is greater, for five years Input Two Independently Configured Inputs; 2-, 3-, and 4-wire RTD, and Ohm, Thermocouple, Millivolt Output 4-20 mA/HART or FOUNDATION fieldbus signal Supply Voltage 12.0 to 42.4 V dc (with 250 ohm load, 18.1 V dc is required)
>Previous  >Next  
Specifiction Packing
  • Performance of PT100 Temperature Transmitter 4-20mA 3144P : *Universally progammable with HART-protocol for various input signals *Two-wire technology, analogue output 4 to 20mA *Highly accurate in entire operating temperature range *Wide voltage supply range *Customer specific measurement range settings *Simple and user friendly software *Multiparametric backlight rotatable LCD display Application of PT100 Temperature Transmitter 4-20mA 3144P : * Temperature Field Transmitter with HART-protocol convert various input signals into a scalable 4 to 20mA analogue output signal *Input Resistance thermometers(RTD) Thermocouples(TC) Resistance transmitters(ohm) Voltage transmitters(mV) Parameters of PT100 Temperature Transmitter 4-20mA 3144P : Digital Accuracy 0.10 C (0.18 F) for Pt100 RTD D/A Accuracy 0.02% of span (Applies to HART/4-20 mA devices) Ambient Temperature Effects 0.0015 C (+0.001% of span for HART/4-20 mA devices) per 1.0 C (1.8 F) change in ambient for a Pt100 RTD Stability (RTDs) 0.1% of reading or 0.1 C, whichever is greater, for two years 0.25% of reading or 0.25 C, whichever is greater, for five years Input Two Independently Configured Inputs; 2-, 3-, and 4-wire RTD, and Ohm, Thermocouple, Millivolt Output 4-20 mA/HART or FOUNDATION fieldbus signal Supply Voltage 12.0 to 42.4 V dc (with 250 ohm load, 18.1 V dc is required)