Location : Home > Products
Products
Yokogawa Temperature Transmitter YTA110 with competitive price
Yokogawa Temperature Transmitter YTA110 with competitive price Introduction: The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to a 4 to 20 mA DC signal for transmission. The YTA110 supports either BRAIN or HART communication protocol. The YTA110 in it standard configuration is certified by TV as complying with SIL2 for safety requirement. Features: High performance Microprocesser-based sensing technology ensures long-term accuracy and high reliability. High reliability: Dual-compartment housing realizes high resistance capability to harsh environments, and YTA110 has SIL2 capability for safety requirement. Variety of sensor inputs: The type of sensor input is user-selectable from thermocouples (T/C), RTDs, ohms, or DC milivolts. Digital communication: BRAIN or HART® communication protocol is available. The insturment configuration can be changed by the user with using the BT200 or HART communicator. Self-diagnostics function: Continuous self-diagnostics capability ensures longterm performance and lower cost of ownership. LCD display with bargraph: The LCD display provides both a digital readout and percent bargraph simultaneously.
>Previous  >Next  
Specifiction Packing
  • Specification: Accuracy (typical) YTA110: 0.1% of span YTA310/320: 0.05% of span Cold junction Compensation accuracy (For T/C only) 0.5 deg C (0.9 deg F) Power supply effect 0.005% of calibration span per volt Ambient temperature effect 0.1%/10 deg C (YTA110) Input signal YTA110/YTA310: single input, YTA320: dual input Input type is selectable: thermocouples, 2-, 3-, and 4-wire RTDs, ohm and DC milivolt Output Two wire 4 to 20 mA DC or FOUNDATION fieldbus signal (YTA320) Supply voltage BRAIN and HART: 10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type) Fieldbus: 9 to 32 V DC (9 to 24 V DC for Entity and 9 to 17.5 V DC for FISCO) Ambient temperature Option code may affect limits -40 to 85 deg C (-40 to 185 deg F) -30 to 80 deg C (-22 to 176 deg F) with integral indicator Mounting Optional mounting bracket can be used either for two-inch pipe or flat panel mounting. Weight 1.2 kg (2.6lb) without integral indicator and mounting bracket. Integral indicator weighs 0.2kg (0.4lb). Degrees of protection IP66, IP67 and NEMA 4X Certificates CENELEC, CSA, FM, IECEx or TIIS SIL Certificate Certified by TV NORD in compliance with the IEC61508 SIL 2 capability for single transmitter use.